Design and repair the connection detail between the TSR Metal roofing and the EPDM flat roof.
The client had been experiencing leaking at this transition for several years, they had multiple companies try and complete repairs but were unable to successfully solve the issue. The client tasked us to create a solution which would solve this. In order to complete this, we investigated the area and deemed the cause to be, due to the lower flat roof being a later addition, the contractor had not tied the roof vapour barriers together properly. The leaking was found to be a result of condensation in the transition detail. Our proposed solution was quite extensive, we created a custom shop drawing to highlight to the client our proposed solution and for better understanding of the cause. This also provided a QC document of the solution solution and repairs needed.
#service #Metal Roof #EPDM #Leak